Series CI4350
PASCAL Ci4 Delta P, highly overload protect.
Application area
For differential pressure and level measurement.
The CI4350 Delta P is highly overload protected and with diaphragm seals it is suitable for differential pressure measurement of aggressive, high viscous and high temperature media.
Features
- Reduced-volume design for diaphragm seal systems with small nominal sizes
- Simultaneous display of differential pressure and static pressure possible
- Long-term stability of 0.1 % within 5 years
- Output functions: linear, invers, square root, table function with up to 64 support points
- Equipped with the LAB4Level operating software, the measuring devices can calculate and display filling level, volume and weight simultaneously
Technical data
Download Data sheetMeasuring range |
|
Media temperature |
|
Ambient temperature |
|
Accuracy |
|
Material wetted parts |
|
Material case |
|
Process connection |
|
Output signal |
|
Requirement |
|
Degree of protection |
|
Certificates
ZER_090
TÜV 13 ATEX 120264 X PASCAL Ci4
ZER_091
IECEx TUN 13.0018X PASCAL Ci4
ZER_121
CML 21UKEX21179X PASCAL Ci4
ZER_042
Profibus PA PASCAL CV
Documentation & Instructions
DB_D4-071-4
Data Sheet
BA_072 (CI4xxx) PASCAL Ci4
Operating instructions
BA_078 (CI4xxx) PASCAL Ci4 LEVEL
Operating instructions
XA_022 (CI4x4x CI435x) PASCAL Ci4
Ex safety instructions
SA_001 (CI4xxx) PASCAL Ci4
SIL instructions / -declarations